Ruud Furnace Troubleshooting Flame Sensor

Ruud Furnace Troubleshooting Flame Sensor. The furnace main gas burners ignite, the main gas burners stay on for only 8 to 10 seconds, then the burners shut. Carrier delivers efficient, dependable performance, inside and out.

622354301 Rheem Ruud Furnace Flame Sensor
622354301 Rheem Ruud Furnace Flame Sensor from arnoldservice.com

A bad flame sensor won’t feel the heat and shut the furnace down when the unit has fired, and it’s already burning hot. Motor parts paint parts panel parts sensor & thermistor parts switch parts thermostat parts transformer parts wire, receptacle & wire connector parts. Typically, the flame sensor comes in the form of a rod that can be found near the back of the furnace, right in the path of the burner.

Sometimes, If The Flame Sensor Is Dirty, It Will Fail To Detect A Flame.


( 2 green & 1 amber light) flame sensors installed with 2 light boards was spliced into the ignitor wires. The most common problem that we see when a flames sensor is not working properly is: 1# shut off electrical power to your furnace.

The Flame Sensor Led Should Be Locked On Bright.not Flickering When Flame Is Present.


The flame sensor monitors the burner to detect whether or not a flame is present. Motor parts paint parts panel parts sensor & thermistor parts switch parts thermostat parts transformer parts wire, receptacle & wire connector parts. If dirty, use a fine abrasive pad to clean the sensor.

To Clean The Sensor, Turn Off Power To The Furnace At The Breaker Box.


Typically, the flame sensor comes in the form of a rod that can be found near the back of the furnace, right in the path of the burner. Sometimes, if the flame sensor is dirty, it will fail to detect a flame. The furnace main gas burners ignite, the main gas burners stay on for only 8 to 10 seconds, then the burners shut.

Streamlined Version Of A Previous Video!I Thought I Was Going To Have To Call An Hvac Tech To Fix This, Which Is Why It Went Unfixed For So Many Years.


Finally, reattach the sensor and resume power to the furnace. If faulty, replace the flame sensor. If faulty, replace the flame sensor.

If It Is Either Defective Or Dirty, It Will Not Be Able To Detect A Flame.


Ruud furnace issue on upgrade board and flame sensor. If the flame sensor is defective, it might fail to detect a flame. I have a ruud achiever super quiet 80 and the furnace will start for a couple of seconds and then the flame will shut off.